Comparative Assessment of Transthoracic and Transesophageal Echocardiography for Assessment of Grading of Aortic Stenosis in Elective Aortic Valve Replacement Surgeries

Authors

  • Gulam Moinuddin Department of Anesthesia, SMS Medical College and Hospital, Jaipur, India
  • Anjum Saiyed Department of Anesthesia, SMS Medical College and Hospital, Jaipur, India
  • Arun Garg Department of Anesthesia, SMS Medical College and Hospital, Jaipur, India
  • Anuradha Yadav Department of Anesthesia, SMS Medical College and Hospital, Jaipur, India

DOI:

https://doi.org/10.21776/ub.jap.2025.006.03.03

Keywords:

aortic stenosis, transthoracic echocardiography, transesophageal echocardiogram, aortic valve area, pressure gradient, peak jet velocity

Abstract

Background: Aortic stenosis severity assessment plays a central role in determining appropriate clinical management. Variability between imaging modalities may influence diagnostic accuracy and therapeutic decisions. This study aims to compare transthoracic echocardiography and transesophageal echocardiography in grading aortic stenosis among patients undergoing aortic valve replacement.

Methods: This prospective observational study included 50 patients scheduled for aortic valve replacement, each undergoing both transthoracic echocardiography and intraoperative pre-cardiopulmonary bypass transesophageal echocardiography. Aortic valve area (AVA), mean pressure gradient, peak jet velocity, and dimensionless index were measured using standard echocardiographic techniques. Paired comparisons between the two modalities were performed using a paired t-test with α = 0.05 and a 95% confidence interval (CI).

Result: Transthoracic echocardiography yielded a mean aortic valve area of 0.584 ± 0.08 cm², whereas transesophageal echocardiography measured 0.623 ± 0.07 cm², demonstrating a significant difference (p = 0.020). Transesophageal echocardiography reported a lower mean pressure gradient (39.08 ± 6.15 mmHg) and peak jet velocity (3.71 ± 0.42 m/s) compared with transthoracic echocardiography (49.14 ± 7.85 mmHg and 4.23 ± 0.53 m/s, respectively), with both parameters showing statistically significant differences (p < 0.001). No significant difference in the dimensionless index was observed between the two modalities (p = 0.250).

Conclusion: Transesophageal echocardiography presents higher AVA measurements but lower pressure gradients and peak velocity values than transthoracic echocardiography, potentially altering aortic stenosis severity grading. Dimensionless index values remain consistent between modalities. Standardized evaluation protocols are required to guide the selection of the most appropriate imaging modality for accurate assessment of aortic stenosis.

References

1. Whitener G, McKenzie J, Akushevich I, et al. Discordance in grading methods of aortic stenosis by pre-cardiopulmonary bypass transesophageal echocardiography. Anesth Analg. 2016;122(4):953-958. doi:10.1213/ANE.0000000000001099

2. Nanditha S, Malik V, Hasija S, Malhotra P, Sreenivas V, Chauhan S. Comparison of grading of aortic stenosis between transthoracic and transesophageal echocardiography in adult patients undergoing elective aortic valve replacement surgeries: A prospective observational study. Ann Card Anaesth. 2019;22(2):194. doi:10.4103/aca.ACA_4_18

3. Schwartzenberg S, Vaturi M, Kazum S, et al. Comparison of Simultaneous Transthoracic Versus Transesophageal Echocardiography for Assessment of Aortic Stenosis. Am J Cardiol. 2022;163:77-84. doi:10.1016/j.amjcard.2021.09.048

4. Whitener GB, Shanahan PC, Wolf BJ, Finley AC. Grading Aortic Valve Stenosis With Dimensionless Index During Pre-cardiopulmonary Bypass Transesophageal Echocardiography: A Comparison With Transthoracic Echocardiography. J Cardiothorac Vasc Anesth. 2019;33(9):2376-2384. doi:10.1053/j.jvca.2019.03.046

5. Karelas D, Tatsis E, Oikonomidis D, Papadopoulos CH. Diagnostic Challenges in the Management of Aortic Valve Stenosis and the Role of Imaging: A Narrative Review. J Clin Med. 2025;14(4):1231. doi:10.3390/jcm14041231

6. Kebed K, Sun D, Addetia K, Mor-Avi V, Markuzon N, Lang RM. Progression of aortic stenosis and echocardiographic criteria for its severity. Eur Heart J Cardiovasc Imaging. 2020;21(7):737-743. doi:10.1093/ehjci/jeaa075

7. Mehrotra P, Flynn AW, Jansen K, et al. Differential left ventricular outflow tract remodeling and dynamics in aortic stenosis. J Am Soc Echocardiogr. 2015;28(11):1259-1266. doi:10.1016/j.echo.2015.07.018

8. Kanchi M, Manjunath R, Natarajan P, Belani K. Effect of General Endotracheal Anesthesia and Mechanical Ventilation on the Echocardiographic Measurements in Severe Aortic Stenosis. J Indian AcadEchocardiogr Cardiovasc Imaging. 2020;4(3):227-231. doi:10.4103/jiae.jiae_17_20

9. Ozkan A, Hachamovitch R, Kapadia SR, Murat Tuzcu E, Marwick TH. Impact of aortic valve replacement on outcome of symptomatic patients with severe aortic stenosis with low gradient and preserved left ventricular ejection fraction. Circulation. 2013;128(6):622-631. doi:10.1161/CIRCULATIONAHA.112.001094

10. Kihara C, Murata K, Wada Y, et al. Impact of intraoperative transesophageal echocardiography in cardiac and thoracic aortic surgery: Experience in 1011 cases. J Cardiol. 2009;54(2):282-288. doi:10.1016/j.jjcc.2009.06.001

11. Asher SR, Malzberg GW, Ong CS, et al. Joint preoperative transthoracic and intraoperative transoesophageal echocardiographic assessment of functional mitral regurgitation severity provides better association with long-term mortality. Interact Cardiovasc Thorac Surg. 2021;32(1):9-19. doi:10.1093/icvts/ivaa230

12. DeSa TB, Tecson KM, Lander SR, et al. Comparison of Echocardiographic and Catheter Mean Gradient to Assess Stenosis After Transcatheter Aortic Valve Implantation. Am J Cardiol. 2023;191:110-118. doi:10.1016/j.amjcard.2022.12.026

13. Schwartzenberg S, Sagie A, Shapira Y, et al. Echocardiographic Assessment of Aortic Stenosis under Sedation Underestimates Stenosis Severity. J Am Soc Echocardiogr. 2019;32(9):1051-1057. doi:10.1016/j.echo.2019.04.422

14. Rusinaru D, Malaquin D, Maréchaux S, Debry N, Tribouilloy C. Relation of Dimensionless Index to Long-Term Outcome in Aortic Stenosis with Preserved LVEF. JACC Cardiovasc Imaging. 2015;8(7):766-775. doi:10.1016/j.jcmg.2015.01.023

Downloads

Published

2025-12-04 — Updated on 2025-12-05

Issue

Section

Research Articles

How to Cite